- Relationship between Flash Point and Front-end Distillation data of petroleum products, (a Schola

The relationship between Flash Point and Atmospheric front-end Distillation data of petroleum products, normally recorded during the routine testing are correlated during 1986 – 1988 period by a team (S/S RJ Patel, PD Dusane, NS Kamble, SK Shukla at IOC Kandla Laboratory ). The idea was originated from similar literature that time, W.L. Nelson Petroleum Engineering, pg 131, edition 1982, initially put forward in year 1944.


Team under the leadership of the author of this blog could work out a most improved/accurate empirical relationship as given below:


Predicted Abel Flash Point FP = 0.613*IBP + 0.193*T10 - 84.0.


( all temperatures in deg Centigrade, C ).


Where, FP = Abel Flash Point deg, C

IBP= Initial Boiling Point as per ASTM D86 Distillation &

T10 = ASTM D86 Distillation, 10% recovery temperature



The empirical formula has been derived by testing and further revalidated more than 5000 Kerosene, Aviation Turbine fuel, and similar samples from products received at Kandla, which were derived from a wide range of crudes and refineries from Russia, US, Venezuela, China, Gulf countries, Singapore etc beside India. The team was benefitted incidentally since India was importing finished products from a wide global sources during the period mentioned.


Later on, some other work on the same subject appeared and one such very reputed reference is found in API correlation (1997 version). FP = 0.68*T_10%_D86 - 109.6 where FP: flash point , ºF, T_10%_D86 : ASTM D86 10% temperature , ºF. Also, by D.S.J. Jones (Elements of Petroleum Processing-Wiley) is: Flash point = 0.77(ASTM 5% in oF - 150oF).


However, the author claims that the IndianOil Kandla Laboratory team work is more accurate than the other existing known correlation equations, though work done much earlier then, with following features:


It is most accurate, 2 parameters ( IBP and 10%T ) have been correlated rather than one. Flash Point of the sample can be predicted accurately from routine Distillation data. When Distillation data are very accurate, the flash point worked out is within precision of the test methods. Also from Flash point, prediction of either IBP or T10 can be made accurately. This was used extensively for verifying data in many round robin programmes conducted by IndianOil Laboratories.


Performance of equipment/technicians, indirectly verifying accuracy of thermometers, test protocol followed by technician etc is possible. A caution is not out of place that any contaminated samples with volatile products like gasoline will have error like result.


Author acknowledges other team members for their contribution for the efforts towards deriving most accurate relationship equation between Flash point and front end routine distillation data. Hope the Petroleum technical community will be benefited by use of the equation.




References :


http://simulationots.blogspot.in/2013/03/what-are-flash-point-calculation-methods.html


http://www.eng-tips.com/viewthread.cfm?qid=178623

Key Words : Flash Point Abel, Distillation D-86,



****************************************************************************